Afișez 481 - 504 din 1163 de rezultate

Control switch, 4N/O, Ie=12A, FS START>2-0-1<START, 45°, momentary/maintained, 48×48 mm, rear mounting

SKU: 549
Cam switch according to IEC/EN60947, size T0, rear mounting form, snap screw-floor fastener, coupling drive for door or cover, front

Control switch, 4N/O, Iu=10A, FS START>1-0-2<START, 45°, momentary/maintained, 48×48 mm, center mounting

SKU: 971
Mini rotary switch according to IEC/EN60947-3, size TM, 500 V/10A, degree of protection Front IP65, thumb-grip, design general: flush mounting

Control switch, 4p, Ie=12A, 2>0<1, 45°, momentary, replacement switch, base fixing

SKU: 702
Cam switch according to IEC/EN60947, size T0, without handle, snap screw-floor fastener, rated uninterrupted current Iu 20A, rated operating voltage

Control switch, 4p, Ie=12A, FS 0-1, 45°, maintained, 48×48 mm, center mounting

SKU: 508
Cam switch according to IEC/EN60947, size T0, central installation shape fixing hole 22.3 mm, front plate 48×48, degree of protection

Control switch, 4p, Ie=12A, FS 0-1, 45°, maintained, 48×48 mm, center mounting

SKU: 2992
Cam switch according to IEC/EN60947, size T0, central installation shape fixing hole 22.3 mm, front plate 48×48, degree of protection

Control switch, 4p, Ie=12A, FS 0-1, 45°, maintained, 48×48 mm, flush mounting

SKU: 2921
Cam switch according to IEC/EN60947, size T0, installation form, front plate 48×48, degree of protection Front IP65 with black thumb

Control switch, 4p, Ie=12A, FS 0-1, 45°, maintained, 48×48 mm, rear mounting

SKU: 3343
Cam switch according to IEC/EN60947, size T0, rear mounting form, snap screw-floor fastener, coupling drive for door or cover, front

Control switch, 4p, Ie=12A, FS 2>0<1, 45°, momentary, 48×48 mm, flush mounting

SKU: 701
Cam switch according to IEC/EN60947, size T0, installation form, front plate 48×48, degree of protection Front IP65 with black thumb

Control switch, 4p, Ie=12A, FS 2>0<1, 45°, momentary, 48×48 mm, rear mounting

SKU: 703
Cam switch according to IEC/EN60947, size T0, rear mounting form, snap screw-floor fastener, coupling drive for door or cover, front

Control switch, 4p, Ie=25A, FS STOP-START, 45°, maintained, 48×48 mm, center mounting

SKU: 1017
Cam switch according to IEC/EN60947, size T3, central installation shape fixing hole 22.3 mm, front plate 48×48, degree of protection

Control switch, 6N/O, Ie=12A, FS 2-0-1, 45°, maintained, 48×48 mm, center mounting

SKU: 1373
Cam switch according to IEC/EN60947, size T0, central installation shape fixing hole 22.3 mm, front plate 48×48, degree of protection

Control switch, 6N/O, Ie=12A, FS 2-0-1, 45°, maintained, 48×48 mm, flush mounting

SKU: 1315
Cam switch according to IEC/EN60947, size T0, installation form, front plate 48×48, degree of protection Front IP65 with black thumb

Control switch, 6N/O, Ie=12A, FS 2-0<1, 45°, maintained/momentary, 48×48 mm, flush mounting

SKU: 1782
Cam switch according to IEC/EN60947, size T0, installation form, front plate 48×48, degree of protection Front IP65 with black thumb

Control switch, 6N/O, Ie=12A, FS 2>0-1, 45°, momentary/maintained, 48×48 mm, flush mounting

SKU: 2304
Cam switch according to IEC/EN60947, size T0, installation form, front plate 48×48, degree of protection Front IP65 with black thumb

Control switch, 6N/O, Ie=12A, FS 2>0<1, 45°, momentary, 48×48 mm, center mounting

SKU: 2750
Cam switch according to IEC/EN60947, size T0, central installation shape fixing hole 22.3 mm, front plate 48×48, degree of protection

Control switch, 6N/O, Ie=12A, FS 2>0<1, 45°, momentary, 48×48 mm, flush mounting

SKU: 2562
Cam switch according to IEC/EN60947, size T0, installation form, front plate 48×48, degree of protection Front IP65 with black thumb

Control switch, 6N/O, Ie=12A, FS 2>0<1, 45°, momentary, 48×48 mm, rear mounting

SKU: 2922
Cam switch according to IEC/EN60947, size T0, rear mounting form, snap screw-floor fastener, coupling drive for door or cover, front

Control switch, 8N/O, Ie=12A, FS 2-0-1, 90°, maintained, replacement switch, base fixing

SKU: 705
Cam switch according to IEC/EN60947, size T0, without handle, snap screw-floor fastener, rated uninterrupted current Iu 20A, rated operating voltage

Fireman’s switch, for 2 strings, 30A, MC4

SKU: 25345
In case of fire, the PV multiple fireman’s switch disconnects the DC line between PV modules and inverter thus preventing

Fireman’s switch, for 2 strings, 30A, MV

SKU: 25346
In case of fire, the PV multiple fireman’s switch disconnects the DC line between PV modules and inverter thus preventing

Fireman’s switch, for 3 strings, 30A, MC4

SKU: 25347
In case of fire, the PV multiple fireman’s switch disconnects the DC line between PV modules and inverter thus preventing

Fireman’s switch, for 3 strings, 30A, MV

SKU: 25348
In case of fire, the PV multiple fireman’s switch disconnects the DC line between PV modules and inverter thus preventing

Fireman’s switch, for 4 strings, 30A, MC4

SKU: 25349
In case of fire, the PV multiple fireman’s switch disconnects the DC line between PV modules and inverter thus preventing

Fireman’s switch, for 4 strings, 30A, MV

SKU: 25363
In case of fire, the PV multiple fireman’s switch disconnects the DC line between PV modules and inverter thus preventing