The types of DS6 series are soft starters for applications with normal switching frequency for the performance range from 22 kW to 110 kW.All versions allow a significant reduction of the inrush current for lamps and heaters (with an unearthed star point) by setting a short soft start ramp time (at least 1 s). the special actuation method (asymmetrical trigger phase control / Eaton patent) for the soft starter function avoids the DC components that would normally occur in two-phase-controlled soft starters. This suppresses the generation of an elliptical rotating field, which would cause uneven motor starting and increase the motor’s acceleration.the true run behavior of the DS6 is therefore comparable with that of a three-phase-controlled soft starter.The ramp time and the start voltage can be set using a potentiometer. The time can be adjusted between 1 to 30 s (start) or 0 to 30 s (stop), the starting voltage (starting torque) from 30 to 100 % mains voltage. Internal bypass relay in DS6-340-MX models: switches on automatically after the end of the ramp, bypassing the internal thyristors. typical fields of application for the soft starter: pump drive pressure surges are avoided by the soft start. The mechanical load on the whole plant is reduced and its service life increases. Fan drives: soft starting prevents drive belt slippage and premature wear. This reduces operating costs and extends the service life of the system. Conveyors: the conveyor belt starts up gently instead of with a jerk. the conveyed goods do not fall over, the mechanical stress on the conveyor is reduced and its lifespan increased.
Soft starter, 3p, 22kW, Ie=41A
0,00 lei
SKU:
4487
Categorii: Materiale pentru uz industrial joasa tensiune, Starter Soft
Descriere
Informații suplimentare
Rated operation current Ie at 40 °C Tu | |
---|---|
Rated operating voltage Ue | |
Rated power three-phase motor, inline, at 230 V | |
Rated power three-phase motor, inline, at 400 V | |
Rated power three-phase motor, inside delta, at 230 V | |
Rated power three-phase motor, inside delta, at 400 V | |
Rated surrounding temperature without derating | |
Rated control supply voltage Us at AC 50HZ | |
Rated control supply voltage Us at AC 60HZ | |
Voltage type for actuating | |
Integrated motor overload protection |
Care sunt costurile de livrare?


Care sunt costurile de livrare?
Costul livrării variază în funcție de volumul și greutatea coletului, începând de la 50 lei.
Costul final va fi calculat în oferta de pret transmisa catre client.
Termenul de livrare pentru produsele stoc sunt 3-5 zile.
Termenul de livrare pentru produsele altele decat stoc, pe baza de comanda intern si/sau extern, este de 7-21 zile (se specifica in oferta).
Transportul se face cu flota proprie pentru cantitati/greutate mare.
Pentru transport curier, acesta se face prin dragon star, sau pallex.
Toate informatiile referitoare la tip transport, cost livrare, termen livrare si alte informatii (ex: greutate/volum), se vor specifica in oferta finala catre client
Valoare MINIMA livrare = 300ron+tva
Pentru detalii nu ezitati sa ne contactati.
Produse similare
Coding switch, Iu=10A, BCD, FS 0-9, 30°, maintained, 30×30 mm, center mounting
SKU:
28
Contactor relay, 3N/O+1N/C, AC
SKU:
14
Contactor, 3p+1N/C, 4kW/400V/AC3
SKU:
9
Contactor, 3p+1N/O, 4kW/400V/AC3
SKU:
11
Contactor, 4p, 4kW/400V/AC3
SKU:
7
Neutral conductor, 4th pole, N for P1Z
Materiale pentru uz industrial joasa tensiune, Accesorii pentru tehnologia comutatorilor de joasă tensiune
SKU:
20
Reversing switch, 2p, Ie=25A, FS 1-0-2, 45°, maintained, 48×48 mm, center mounting
SKU:
21
Reversing switch, 3p, Ie=25A, FS 1-0-2, 45°, maintained, 48×48 mm, center mounting
SKU:
25









